Use ping to check that the connection between CC-SG computer and a particular IP address is working correctly.
Note: Some sites explicitly block ping requests. Verify that the target and intervening network allow pings if a ping is unsuccessful.
Option |
Description |
---|---|
Show other received ICMP packets |
Verbose output, which lists other received ICMP packets in addition to ECHO_RESPONSE packets. Rarely seen. |
No DNS Resolution |
Does not resolve addresses to host names. |
Record Route |
Records route. Turns on the IP record route option, which will store the route of the packet inside the IP header. |
Use Broadcast Address |
Allows pinging a broadcast message. |
Adaptive Timing |
Adaptive ping. Interpacket interval adapts to round-trip time, so that effectively not more than one unanswered probes present in the network. Minimal interval is 200 msec. |
Note: Press CTRL+Q to display a statistics summary for the session so far and continue to ping the destination.