You can enable the remote system monitoring feature to use the GKrellM tool. The GKrellM tool provides a graphical view of resource utilization on the CC-SG unit. This tool is similar to the Windows Task Manager's Performance tab.
1: Enable remote system monitoring for the CC-SG unit:
Choose Operation > Utilities > Remote System Monitoring.
Select Enabled in the Remote Monitoring Service field.
Enter the IP address of the client PC you want to allow to monitor the CC-SG unit in the Allowed Remote Monitoring IP Addresses field. You can enter up to three IP addresses.
The default port for the GKrellM tool is 19150. You can change the port.
Select Submit.
2: Download the remote system monitoring client software:
Navigate to www.gkrellm.net.
Download and install the package that is appropriate for your client PC.
3: Configure the remote system monitoring client to work with CC-SG:
Follow the instructions in the Read Me file to set the CC-SG unit as the target to monitor.
Windows users must use the command line to locate the Gkrellm installation directory and then run the commands specified in the Read.