Configure Virtual Media Shared Images when using virtual media to access file server ISO images. ISO9660 format is the standard supported. However, other CD-ROM extensions may also work.
Note: SMB/CIFS support is required on the file server.
To designate file server ISO images for virtual media access:
Click Device Settings > Virtual Media Shared Images.
Click New to add a shared image.
Enter information about the file server ISO images that you want to access:
IP Address/Host Name: Host name or IP address of the file server. Up to 248 characters.
Share Name: Share name portion of the ISO image.
Image Path: Full path name of the location of the ISO image. For example, /path0/image0.iso, \path1\image1.iso, and so on.
Select the Enable Samba 1.0 checkbox to allow Dominion KX IV–101 to use an older Samba version. When unchecked, Samba 3.0 is used.