Note: It is recommended that you save the audit log prior to performing a factory reset.
The audit log is deleted when a factory reset is performed and the reset event is not logged in the audit log. For more information about saving the audit log, see Audit Log.
To perform a factory reset:
Choose Maintenance > Factory Reset. The Factory Reset page opens.
Choose the appropriate reset option from the following options:
Full Factory Reset - Removes the entire configuration and resets the device completely to the factory defaults. Note that any management associations with CommandCenter will be broken. Because of the complete nature of this reset, you will be prompted to confirm the factory reset.
Network Parameter Reset - Resets the network parameters of the device back to the default values (click Device Settings > Network Settings to access this information).
Click Reset to continue. You will be prompted to confirm the factory reset because all network settings will be permanently lost.
Click OK proceed. Upon completion, the KX III device is automatically restarted.