usermgmt::UserManager_1_0_3 Interface Reference

User manager interface More...

import"UserManager.idl";

Public Member Functions

vector< string > getAccountNames ()
 Get a list of account names available on the system. More...
 
int createAccount (in string username, in string password)
 Create a new account. More...
 
int deleteAccount (in string username)
 Deletes an account. More...
 
vector< AccountgetAllAccounts ()
 Get information about all available user accounts. More...
 
int createAccountFull (in string username, in string password, in UserInfo info)
 Create a new account with defined settings. More...
 
vector< AccountgetAccountsByRole (in string roleName)
 Get a list of accounts that have a given role. More...
 
Preferences getDefaultPreferences ()
 Get default user preferences. More...
 
int setDefaultPreferences (in Preferences prefs)
 Set default user preferences. More...
 

Public Attributes

constant int ERR_USER_DOESNT_EXIST = 1
 A user with the given name does not exist.
 
constant int ERR_USER_NOT_DELETABLE = 2
 The user is not deletable.
 
constant int ERR_USER_ALREADY_EXISTS = 1
 A user with the given name already exists.
 
constant int ERR_MAX_USERS_REACHED = 2
 Maximum number of users reached.
 
constant int ERR_PASSWORD_TOO_SHORT_FOR_SNMP = 3
 The password is too short to be used as SNMPv3 passphrase.
 
constant int ERR_INVALID_VALUE = 4
 Invalid arguments.
 
constant int ERR_PASSWORD_EMPTY = 5
 The password must not be empty.
 
constant int ERR_PASSWORD_TOO_SHORT = 6
 The password is too short.
 
constant int ERR_PASSWORD_TOO_LONG = 7
 The password is too long.
 
constant int ERR_PASSWORD_CTRL_CHARS = 8
 The password must not contain control characters.
 
constant int ERR_PASSWORD_NEED_LOWER = 9
 The password must contain at least one lower-case character.
 
constant int ERR_PASSWORD_NEED_UPPER = 10
 The password must contain at least one upper-case character.
 
constant int ERR_PASSWORD_NEED_NUMERIC = 11
 The password must contain at least one numeric character.
 
constant int ERR_PASSWORD_NEED_SPECIAL = 12
 The password must contain at least one special character.
 
constant int ERR_SSH_PUBKEY_DATA_TOO_LARGE = 14
 The ssh public key data is too large.
 
constant int ERR_SSH_PUBKEY_INVALID = 15
 The ssh public key is invalid.
 
constant int ERR_SSH_PUBKEY_NOT_SUPPORTED = 16
 The ssh public key is not supported.
 
constant int ERR_SSH_RSA_PUBKEY_TOO_SHORT = 17
 The ssh RSA public key is too short.
 

Detailed Description

User manager interface

Member Function Documentation

int usermgmt::UserManager_1_0_3::createAccount ( in string  username,
in string  password 
)

Create a new account.

Parameters
usernameNew user name
passwordNew password
Returns
0 if OK
1 if a user with the given name already exists
2 if the maximum number of users is reached
3 SNMPv3 USM is activated for the user and the password shall be used as auth passphrase. For this case, the password is too short (must be at least 8 characters).
4 if user name is invalid
5 The password must not be empty.
6 The password is too short.
7 The password is too long.
8 The password must not contain control characters.
9 The password has to contain at least one lower case character.
10 The password has to contain at least one upper case character.
11 The password has to contain at least one numeric character.
12 The password has to contain at least one printable special character.
int usermgmt::UserManager_1_0_3::createAccountFull ( in string  username,
in string  password,
in UserInfo  info 
)

Create a new account with defined settings.

Parameters
usernameNew user name
passwordNew password
infoNew user information
Returns
0 if OK
1 if a user with the given name already exists
2 if the maximum number of users is reached
3 SNMPv3 USM is activated for the user and the password shall be used as auth passphrase. For this case, the password is too short (must be at least 8 characters).
4 if any value except password is invalid
5 The password must not be empty.
6 The password is too short.
7 The password is too long.
8 The password must not contain control characters.
9 The password has to contain at least one lower case character.
10 The password has to contain at least one upper case character.
11 The password has to contain at least one numeric character.
12 The password has to contain at least one printable special character.
14 The ssh public key data is too large.
15 The ssh public key is invalid.
16 The ssh public key is not supported.
17 The ssh RSA public key is too short.
int usermgmt::UserManager_1_0_3::deleteAccount ( in string  username)

Deletes an account.

Parameters
usernameName of user to delete
Returns
0 if OK
1 if a user with the given name does not exist
2 if the user cannot be deleted
vector<string> usermgmt::UserManager_1_0_3::getAccountNames ( )

Get a list of account names available on the system.

Returns
List of account names
vector<Account> usermgmt::UserManager_1_0_3::getAccountsByRole ( in string  roleName)

Get a list of accounts that have a given role.

Parameters
roleNameRole name
Returns
List of accounts
vector<Account> usermgmt::UserManager_1_0_3::getAllAccounts ( )

Get information about all available user accounts.

Returns
List of accounts
Preferences usermgmt::UserManager_1_0_3::getDefaultPreferences ( )

Get default user preferences.

Returns
Default user preferences.
int usermgmt::UserManager_1_0_3::setDefaultPreferences ( in Preferences  prefs)

Set default user preferences.

Parameters
prefsDefault user preferences.
Returns
0 if OK

The documentation for this interface was generated from the following file: