pdumodel::PowerQualitySensor Interface Reference

Power quality sensor interface. More...

Inheritance diagram for pdumodel::PowerQualitySensor:
sensors::StateSensor sensors::Sensor

Public Attributes

constant int STATE_NORMAL = 0
 Power quality is normal.
 
constant int STATE_WARNING = 1
 Power quality is warning.
 
constant int STATE_CRITICAL = 2
 Power quality is critical.
 
- Public Attributes inherited from sensors::Sensor
constant int ERR_NOT_SUPPORTED = 1
 The operation is not supported.
 
constant int NUMERIC = 0
 Sensor reading type
 
constant int DISCRETE_ON_OFF = 1
 
constant int DISCRETE_MULTI = 2
 
constant int UNSPECIFIED = 0
 Sensor type
 
constant int VOLTAGE = 1
 
constant int CURRENT = 2
 
constant int UNBALANCE_CURRENT = 3
 
constant int POWER = 4
 
constant int POWER_FACTOR = 5
 
constant int ENERGY = 6
 
constant int FREQUENCY = 7
 
constant int TEMPERATURE = 8
 
constant int HUMIDITY = 9
 
constant int AIR_FLOW = 10
 
constant int AIR_PRESSURE = 11
 
constant int CONTACT_CLOSURE = 12
 
constant int ON_OFF_SENSOR = 13
 
constant int TRIP_SENSOR = 14
 
constant int VIBRATION = 15
 
constant int WATER_LEAK = 16
 
constant int SMOKE_DETECTOR = 17
 
constant int TOTAL_HARMONIC_DISTORTION = 18
 
constant int MASS = 19
 
constant int ELECTRICAL_RESISTANCE = 20
 
constant int FLUX = 21
 
constant int LUMINOUS_INTENSITY = 22
 
constant int ACCELERATION = 23
 
constant int MAGNETIC_FLUX_DENSITY = 24
 
constant int ELECTRIC_FIELD_STRENGTH = 25
 
constant int MAGNETIC_FIELD_STRENGTH = 26
 
constant int ANGLE = 27
 
constant int SELECTION = 28
 
constant int FAULT_STATE = 29
 
constant int POWER_QUALITY = 30
 
constant int ROTATIONAL_SPEED = 31
 
constant int LUMINOUS_ENERGY = 32
 
constant int LUMINOUS_FLUX = 33
 
constant int ILLUMINANCE = 34
 
constant int LUMINOUS_EMITTANCE = 35
 
constant int MOTION = 36
 
constant int OCCUPANCY = 37
 
constant int TAMPER = 38
 
constant int DRY_CONTACT = 39
 
constant int POWERED_DRY_CONTACT = 40
 
constant int ABSOLUTE_HUMIDITY = 41
 
constant int DOOR_STATE = 42
 
constant int DOOR_LOCK_STATE = 43
 
constant int DOOR_HANDLE_LOCK = 44
 
constant int CREST_FACTOR = 45
 
constant int DISTANCE = 46
 
constant int LENGTH = 47
 
constant int UNBALANCE_VOLTAGE = 48
 
constant int PARTICLE_DENSITY = 49
 
constant int DEW_POINT = 50
 
constant int ELECTRICAL_IMPEDANCE = 51
 
constant int TS_BYPASS_STATE = 52
 
constant int BATTERY_LEVEL = 53
 
constant int NONE = 0
 Sensor unit
 
constant int VOLT = 1
 
constant int AMPERE = 2
 
constant int WATT = 3
 
constant int VOLT_AMP = 4
 
constant int WATT_HOUR = 5
 
constant int VOLT_AMP_HOUR = 6
 
constant int DEGREE_CELSIUS = 7
 
constant int HZ = 8
 
constant int PERCENT = 9
 
constant int METER_PER_SEC = 10
 
constant int PASCAL = 11
 
constant int G = 12
 
constant int RPM = 13
 
constant int METER = 14
 
constant int HOUR = 15
 
constant int MINUTE = 16
 
constant int SECOND = 17
 
constant int VOLT_AMP_REACTIVE = 18
 
constant int VOLT_AMP_REACTIVE_HOUR = 19
 
constant int GRAM = 20
 
constant int OHM = 21
 
constant int LITERS_PER_HOUR = 22
 
constant int CANDELA = 23
 
constant int METER_PER_SQUARE_SEC = 24
 
constant int METER_PER_SQARE_SEC = 24
 
constant int TESLA = 25
 
constant int VOLT_PER_METER = 26
 
constant int VOLT_PER_AMPERE = 27
 
constant int DEGREE = 28
 
constant int DEGREE_FAHRENHEIT = 29
 
constant int KELVIN = 30
 
constant int JOULE = 31
 
constant int COULOMB = 32
 
constant int NIT = 33
 
constant int LUMEN = 34
 
constant int LUMEN_SECOND = 35
 
constant int LUX = 36
 
constant int PSI = 37
 
constant int NEWTON = 38
 
constant int FOOT = 39
 
constant int FOOT_PER_SEC = 40
 
constant int CUBIC_METER = 41
 
constant int RADIANT = 42
 
constant int STERADIANT = 43
 
constant int HENRY = 44
 
constant int FARAD = 45
 
constant int MOL = 46
 
constant int BECQUEREL = 47
 
constant int GRAY = 48
 
constant int SIEVERT = 49
 
constant int G_PER_CUBIC_METER = 50
 
constant int UG_PER_CUBIC_METER = 51
 

Additional Inherited Members

- Public Types inherited from sensors::Sensor
enum  OnOffState { OFF , ON }
 Sensor states for DISCRETE_ON_OFF sensors. More...
 
enum  OpenClosedState { OPEN , CLOSED }
 
enum  NormalAlarmedState { NORMAL , ALARMED }
 
enum  OkFaultState { OK , FAULT }
 
- Public Member Functions inherited from sensors::StateSensor
State getState ()
 Get the sensor state.
 
- Public Member Functions inherited from sensors::Sensor
TypeSpec getTypeSpec ()
 Retrieve the sensor type specification.
 
boolean isTypeChangeAllowed ()
 Check whether the sensor type can be changed using setType().
 
int setType (in int type, in int unit)
 Set sensor type and unit.
 

Detailed Description

Power quality sensor interface.

Definition at line 17 of file PowerQualitySensor.idl.

Member Data Documentation

◆ STATE_CRITICAL

constant int pdumodel::PowerQualitySensor::STATE_CRITICAL = 2

Power quality is critical.

Definition at line 21 of file PowerQualitySensor.idl.

◆ STATE_NORMAL

constant int pdumodel::PowerQualitySensor::STATE_NORMAL = 0

Power quality is normal.

Definition at line 19 of file PowerQualitySensor.idl.

◆ STATE_WARNING

constant int pdumodel::PowerQualitySensor::STATE_WARNING = 1

Power quality is warning.

Definition at line 20 of file PowerQualitySensor.idl.


The documentation for this interface was generated from the following file: