Legrand / Raritan / Server Technology Xerus™ JSON-RPC API
Loading...
Searching...
No Matches
Classes | Public Member Functions | Public Attributes | List of all members
sensors::NumericSensor Interface Reference

A sensor with numeric readings. More...

Inheritance diagram for sensors::NumericSensor:
sensors::Sensor pdumodel::TypeBResidualCurrentNumericSensor pdumodel::VoltageMonitoringSensor sensors::AccumulatingNumericSensor

Classes

struct  DefaultThresholdsChangedEvent
 Event: Sensor default thresholds have changed. More...
 
struct  MetaData
 Numeric sensor metadata. More...
 
struct  MetaDataChangedEvent
 Event: Sensor metadata has changed. More...
 
struct  MinMax
 Numeric sensor minimum / maximum values. More...
 
struct  MinMaxChangedEvent
 Event: Sensor min or max value has changed. More...
 
struct  MinMaxResetEvent
 Event: Min / Max value has been reset. More...
 
struct  Range
 Range of possible sensor readings. More...
 
struct  Reading
 Numeric sensor reading. More...
 
struct  ReadingChangedEvent
 Event: Numeric sensor reading has changed. More...
 
struct  StateChangedEvent
 Event: Sensor state has changed. More...
 
struct  ThresholdCapabilities
 Threshold capabilities. More...
 
struct  Thresholds
 Numeric sensor thresholds. More...
 
struct  ThresholdsChangedEvent
 Event: Sensor thresholds have changed. More...
 

Public Member Functions

MetaData getMetaData ()
 Retrieve the sensor metadata. More...
 
Thresholds getDefaultThresholds ()
 Retrieve the sensor default thresholds. More...
 
Thresholds getThresholds ()
 Retrieve the thresholds. More...
 
int setThresholds (in Thresholds thresh)
 Change the thresholds. More...
 
Reading getReading ()
 Get the sensor reading. More...
 
MinMax getMinMax ()
 Get the min / max of sensor value. More...
 
void resetMinMax ()
 Reset min / max of sensor value.
 
- Public Member Functions inherited from sensors::Sensor
TypeSpec getTypeSpec ()
 Retrieve the sensor type specification. More...
 
boolean isTypeChangeAllowed ()
 Check whether the sensor type can be changed using setType(). More...
 
int setType (in int type, in int unit)
 Set sensor type and unit. More...
 

Public Attributes

constant int THRESHOLD_OUT_OF_RANGE = 1
 The threshold exceedes the sensor range.
 
constant int THRESHOLD_INVALID = 2
 The threshold constraints are not met.
 
constant int THRESHOLD_NOT_SUPPORTED = 3
 The sensor does not support setting this threshold.
 
- Public Attributes inherited from sensors::Sensor
constant int ERR_NOT_SUPPORTED = 1
 The operation is not supported.
 
constant int NUMERIC = 0
 Sensor reading type
 
constant int DISCRETE_ON_OFF = 1
 
constant int DISCRETE_MULTI = 2
 
constant int UNSPECIFIED = 0
 Sensor type
 
constant int VOLTAGE = 1
 
constant int CURRENT = 2
 
constant int UNBALANCE_CURRENT = 3
 
constant int POWER = 4
 
constant int POWER_FACTOR = 5
 
constant int ENERGY = 6
 
constant int FREQUENCY = 7
 
constant int TEMPERATURE = 8
 
constant int HUMIDITY = 9
 
constant int AIR_FLOW = 10
 
constant int AIR_PRESSURE = 11
 
constant int CONTACT_CLOSURE = 12
 
constant int ON_OFF_SENSOR = 13
 
constant int TRIP_SENSOR = 14
 
constant int VIBRATION = 15
 
constant int WATER_LEAK = 16
 
constant int SMOKE_DETECTOR = 17
 
constant int TOTAL_HARMONIC_DISTORTION = 18
 
constant int MASS = 19
 
constant int ELECTRICAL_RESISTANCE = 20
 
constant int FLUX = 21
 
constant int LUMINOUS_INTENSITY = 22
 
constant int ACCELERATION = 23
 
constant int MAGNETIC_FLUX_DENSITY = 24
 
constant int ELECTRIC_FIELD_STRENGTH = 25
 
constant int MAGNETIC_FIELD_STRENGTH = 26
 
constant int ANGLE = 27
 
constant int SELECTION = 28
 
constant int FAULT_STATE = 29
 
constant int POWER_QUALITY = 30
 
constant int ROTATIONAL_SPEED = 31
 
constant int LUMINOUS_ENERGY = 32
 
constant int LUMINOUS_FLUX = 33
 
constant int ILLUMINANCE = 34
 
constant int LUMINOUS_EMITTANCE = 35
 
constant int MOTION = 36
 
constant int OCCUPANCY = 37
 
constant int TAMPER = 38
 
constant int DRY_CONTACT = 39
 
constant int POWERED_DRY_CONTACT = 40
 
constant int ABSOLUTE_HUMIDITY = 41
 
constant int DOOR_STATE = 42
 
constant int DOOR_LOCK_STATE = 43
 
constant int DOOR_HANDLE_LOCK = 44
 
constant int CREST_FACTOR = 45
 
constant int DISTANCE = 46
 
constant int LENGTH = 47
 
constant int UNBALANCE_VOLTAGE = 48
 
constant int PARTICLE_DENSITY = 49
 
constant int DEW_POINT = 50
 
constant int ELECTRICAL_IMPEDANCE = 51
 
constant int NONE = 0
 Sensor unit
 
constant int VOLT = 1
 
constant int AMPERE = 2
 
constant int WATT = 3
 
constant int VOLT_AMP = 4
 
constant int WATT_HOUR = 5
 
constant int VOLT_AMP_HOUR = 6
 
constant int DEGREE_CELSIUS = 7
 
constant int HZ = 8
 
constant int PERCENT = 9
 
constant int METER_PER_SEC = 10
 
constant int PASCAL = 11
 
constant int G = 12
 
constant int RPM = 13
 
constant int METER = 14
 
constant int HOUR = 15
 
constant int MINUTE = 16
 
constant int SECOND = 17
 
constant int VOLT_AMP_REACTIVE = 18
 
constant int VOLT_AMP_REACTIVE_HOUR = 19
 
constant int GRAM = 20
 
constant int OHM = 21
 
constant int LITERS_PER_HOUR = 22
 
constant int CANDELA = 23
 
constant int METER_PER_SQUARE_SEC = 24
 
constant int METER_PER_SQARE_SEC = 24
 
constant int TESLA = 25
 
constant int VOLT_PER_METER = 26
 
constant int VOLT_PER_AMPERE = 27
 
constant int DEGREE = 28
 
constant int DEGREE_FAHRENHEIT = 29
 
constant int KELVIN = 30
 
constant int JOULE = 31
 
constant int COULOMB = 32
 
constant int NIT = 33
 
constant int LUMEN = 34
 
constant int LUMEN_SECOND = 35
 
constant int LUX = 36
 
constant int PSI = 37
 
constant int NEWTON = 38
 
constant int FOOT = 39
 
constant int FOOT_PER_SEC = 40
 
constant int CUBIC_METER = 41
 
constant int RADIANT = 42
 
constant int STERADIANT = 43
 
constant int HENRY = 44
 
constant int FARAD = 45
 
constant int MOL = 46
 
constant int BECQUEREL = 47
 
constant int GRAY = 48
 
constant int SIEVERT = 49
 
constant int G_PER_CUBIC_METER = 50
 
constant int UG_PER_CUBIC_METER = 51
 

Additional Inherited Members

- Public Types inherited from sensors::Sensor
enum  OnOffState { OFF , ON }
 Sensor states for DISCRETE_ON_OFF sensors. More...
 
enum  OpenClosedState { OPEN , CLOSED }
 
enum  NormalAlarmedState { NORMAL , ALARMED }
 
enum  OkFaultState { OK , FAULT }
 

Detailed Description

A sensor with numeric readings.

Member Function Documentation

◆ getDefaultThresholds()

Thresholds sensors::NumericSensor::getDefaultThresholds ( )

Retrieve the sensor default thresholds.

Returns
Set of default thresholds

◆ getMetaData()

MetaData sensors::NumericSensor::getMetaData ( )

Retrieve the sensor metadata.

Returns
Sensor metadata

◆ getMinMax()

MinMax sensors::NumericSensor::getMinMax ( )

Get the min / max of sensor value.

Returns
Sensor min / max values

◆ getReading()

Reading sensors::NumericSensor::getReading ( )

Get the sensor reading.

Returns
Sensor reading, not rounded

◆ getThresholds()

Thresholds sensors::NumericSensor::getThresholds ( )

Retrieve the thresholds.

Note: In case of peripheral devices these thresholds may be overridden by the device slot configuration.

Returns
Set of configured thresholds

◆ setThresholds()

int sensors::NumericSensor::setThresholds ( in Thresholds  thresh)

Change the thresholds.

Note: In case of peripheral devices these thresholds may be overridden by the device slot configuration.

Parameters
threshNew set of thresholds
Returns
0 if OK
THRESHOLD_OUT_OF_RANGE if any threshold is out of range
THRESHOLD_INVALID if thresholds don't meet the requirements
THRESHOLD_NOT_SUPPORTED if threshold is not supported

The documentation for this interface was generated from the following file: