Server Monitor Interface.
More...
import"ServerMonitor.idl";
|
enum | ServerReachability { WAITING
, REACHABLE
, UNREACHABLE
, ERROR
} |
| Server Reachability State. More...
|
|
enum | ServerPowerState { UNKNOWN
, ON
, OFF
, SHUTTING_DOWN
} |
| Server Power Control State. More...
|
|
enum | ServerPowerControlResult {
NO_ERROR
, SHUTDOWN_CMD_FAILED
, SWITCHING_OFF_FAILED
, SWITCHING_ON_FAILED
,
POWER_CHECK_TIMEOUT
} |
| Server Power Control Result. More...
|
|
enum | ServerPowerCheckMethod { TIMER
, POWER_DROP
} |
| Methods of checking power state. More...
|
|
Server Monitor Interface.
◆ ServerPowerCheckMethod
Methods of checking power state.
Enumerator |
---|
TIMER | Server is assumed to be off after a time interval.
|
POWER_DROP | Server is off if power consumption dropped.
|
◆ ServerPowerControlResult
Server Power Control Result.
Enumerator |
---|
NO_ERROR | No error, operation may still be in progress.
|
SHUTDOWN_CMD_FAILED | Error issuing the shutdown command to the server.
|
SWITCHING_OFF_FAILED | Switching the outlet or outlet group off failed.
|
SWITCHING_ON_FAILED | Switching the outlet or outlet group on failed.
|
POWER_CHECK_TIMEOUT | Checking if power is off timed out.
|
◆ ServerPowerState
Server Power Control State.
Enumerator |
---|
UNKNOWN | Power state currently not known.
|
ON | Server power target is on.
|
OFF | Server power target is off.
|
SHUTTING_DOWN | Server is being manually shut down.
|
◆ ServerReachability
Server Reachability State.
Enumerator |
---|
WAITING | Waiting for reliable connection.
|
REACHABLE | Server is up and running.
|
UNREACHABLE | No response from server.
|
ERROR | Error pinging server (e.g. DNS lookup failure)
|
◆ addServer()
int servermon::ServerMonitor::addServer |
( |
out int |
id, |
|
|
in ServerSettings |
settings |
|
) |
| |
Add a new server entry.
- Parameters
-
id | New entry id, automatically assigned |
settings | New server settings |
- Returns
- 0 if OK
-
2 if the settings are invalid
-
3 if an entry for the given hostname exists
-
4 if the maximum number of servers is reached
- Note
- The ServerSettings structure can be "sparse"; fields missing in the JSON representation will be set to default values.
◆ deleteServer()
int servermon::ServerMonitor::deleteServer |
( |
in int |
id | ) |
|
Delete a server entry.
- Parameters
-
- Returns
- 0 if OK
-
1 if the entry does not exist
◆ getServer()
int servermon::ServerMonitor::getServer |
( |
out Server |
server, |
|
|
in int |
id |
|
) |
| |
Retrieve a server entry (settings and status).
- Parameters
-
server | Server settings and status |
id | Entry id |
- Returns
- 0 if OK
-
1 if the entry does not exist
◆ listServers()
map<int, Server> servermon::ServerMonitor::listServers |
( |
| ) |
|
Retrieve a list of server entries (settings and status).
- Returns
- Server list
◆ modifyServer()
int servermon::ServerMonitor::modifyServer |
( |
in int |
id, |
|
|
in ServerSettings |
settings |
|
) |
| |
Modify an existing server entry.
- Parameters
-
id | Entry id |
settings | New settings |
- Returns
- 0 if OK
-
1 if the entry does not exist
-
2 if the settings are invalid
-
3 if an entry for the given hostname exists
- Note
- The ServerSettings structure can be "sparse"; fields missing in the JSON representation will remain unchanged.
◆ powerControl()
int servermon::ServerMonitor::powerControl |
( |
in int |
id, |
|
|
in boolean |
on |
|
) |
| |
Control the power state of the outlets the server uses.
Attempting to switch the power off will issue a graceful shutdown of the server beforehand.
- Parameters
-
id | Entry id |
on | Switch power on if true, off if false |
- Returns
- 0 if OK
-
1 if the entry does not exist
-
2 if the settings are invalid
The documentation for this interface was generated from the following file: