To run the Active Directory® script on a Windows 2003® server, use the script provided by Microsoft® (available on the Windows 2003 server installation CD). These scripts are loaded onto your system with a Microsoft® Windows 2003 installation. ADSI (Active Directory Service Interface) acts as a low-level editor for Active Directory, allowing you to perform common administrative tasks such as adding, deleting, and moving objects with a directory service.
To edit the individual user attributes within the group rciusergroup:
From the installation CD, choose Support > Tools.
Double-click SUPTOOLS.MSI to install the support tools.
Go to the directory where the support tools were installed. Run adsiedit.msc. The ADSI Edit window opens.
Open the Domain.
In the left pane of the window, select the CN=Users folder.
Locate the user name whose properties you want to adjust in the right pane. Right-click the user name and select Properties.
Click the Attribute Editor tab if it is not already open. Choose rciusergroup from the Attributes list.
Click Edit. The String Attribute Editor dialog appears.
Type the user group (created in the KX III) in the Edit Attribute field. Click OK.