Well-known URI Interface File/Alias -------------- --------- ---------- /model/inlet alias for /model/pdu/0/inlet /model/ocp alias for /model/pdu/0/ocp /model/outlet alias for /model/pdu/0/outlet /model/outletgroup pdumodel.OutletGroupManager OutletGroupManager.idl /model/outletgroup/ pdumodel.OutletGroup OutletGroup.idl /model/outletgroup//activePower sensors.NumericSensor NumericSensor.idl /model/outletgroup//activeEnergy sensors.NumericSensor NumericSensor.idl /model/pdu/ pdumodel.Pdu Pdu.idl /model/pdu//inlet/ pdumodel.Inlet Inlet.idl /model/pdu//inlet//activeEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu//inlet//activePower sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//apparentEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu//inlet//apparentPower sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//crestFactor sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//current sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//displacementPowerFactor sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//lineFrequency sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//peakCurrent sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//phaseAngle sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//activeEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu//inlet//pole//activePower sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//apparentEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu//inlet//pole//apparentPower sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//current sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//displacementPowerFactor sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//peakCurrent sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//phaseAngle sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//powerFactor sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//reactivePower sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//voltage sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//pole//voltageLN sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//powerFactor sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//powerQuality sensors.StateSensor StateSensor.idl /model/pdu//inlet//reactivePower sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//residualCurrent (Type A) sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//residualCurrent (Type B) pdumodel.TypeBResidualCurrentNumericSensor TypeBResidualCurrentNumericSensor.idl /model/pdu//inlet//residualCurrentStatus pdumodel.ResidualCurrentStateSensor ResidualCurrentStateSensor.idl /model/pdu//inlet//surgeProtectorStatus sensors.StateSensor StateSensor.idl /model/pdu//inlet//unbalancedCurrent sensors.NumericSensor NumericSensor.idl /model/pdu//inlet//voltage sensors.NumericSensor NumericSensor.idl /model/pdu//ocp/ pdumodel.OverCurrentProtector OverCurrentProtector.idl /model/pdu//ocp//activeEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu//ocp//activePower sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//apparentEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu//ocp//apparentPower sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//current sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//displacementPowerFactor sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//lineFrequency sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//maximumCurrent sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//peakCurrent sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//phaseAngle sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//powerFactor sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//reactivePower sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//voltage sensors.NumericSensor NumericSensor.idl /model/pdu//ocp//trip pdumodel.OverCurrentProtectorTripSensor OverCurrentProtectorTripSensor.idl /model/pdu//outlet/ pdumodel.Outlet Outlet.idl /model/pdu//outlet//activeEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu//outlet//activePower sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//apparentEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu//outlet//apparentPower sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//crestFactor sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//current sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//displacementPowerFactor sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//lineFrequency sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//maximumCurrent sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//outletState sensors.StateSensor StateSensor.idl /model/pdu//outlet//peakCurrent sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//phaseAngle sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//powerFactor sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//reactivePower sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//unbalancedCurrent sensors.NumericSensor NumericSensor.idl /model/pdu//outlet//voltage sensors.NumericSensor NumericSensor.idl /model/peripheraldevicemanager peripheral.DeviceManager PeripheralDeviceManager.idl /model/peripheraldeviceslot/ peripheral.DeviceSlot PeripheralDeviceSlot.idl /model/peripheraldeviceslot//device sensors.Sensor Sensor.idl /model/pmc pdumodel.PowerMeterController PowerMeterController.idl /model/unit pdumodel.Unit Unit.idl /model/ade/ pdumodel.Ade Ade.idl /model/bcm pdumodel.Bcm Bcm.idl /model/sensorlogger sensors.Logger SensorLogger.idl /model/assetstriplogger assetmgrmodel.AssetStripLogger AssetStripLogger.idl /model/alertedsensormanager sensors.AlertedSensorManager AlertedSensorManager.idl /auth auth.AuthManager AuthManager.idl /auth/currentUser alias for /auth/user/ /auth/ldap auth.LdapManager LdapManager.idl /auth/radius auth.RadiusManager RadiusManager.idl /auth/role usermgmt.RoleManager RoleManager.idl /auth/role/ usermgmt.Role Role.idl /auth/user usermgmt.UserManager UserManager.idl /auth/user/ usermgmt.User User.idl /bulk bulkrpc.BulkRequest BulkRequest.idl /bulkcfg bulkcfg.BulkConfiguration BulkConfiguration.idl /cardreader smartcard.CardReaderManager CardReaderManager.idl /cascade cascading.CascadeManager CascadeManager.idl /cascading cascading.Cascading Cascading.idl /datapush event.DataPushService DataPushService.idl /datetime datetime.DateTime DateTime.idl /debuglog logging.DebugLog DebugLog.idl /diag diag.DiagLogSettings DiagLogSettings.idl /display display.DisplayControl DisplayControl.idl /dooraccesscontrol smartlock.DoorAccessControl DoorAccessControl.idl /energywise cew.EnergyWiseManager EnergyWiseManager.idl /event_engine event.Engine EventEngine.idl /event_engine/alarms event.AlarmManager AlarmManager.idl /event_engine/timer_events event.TimerEventManager TimerEventManager.idl /eventlog logging.EventLog EventLog.idl /eventservice event.Service EventService.idl /firmware firmware.Firmware Firmware.idl /cgi-bin/fwupdate_progress.cgi firmware.UpdateStatus FirmwareUpdateStatus.idl /fitness fitness.Fitness Fitness.idl /hwhealth fitness.HardwareHealth HardwareHealth.idl /keypad smartlock.KeypadManager KeypadManager.idl /lhx lhx.Support LhxSupport.idl /luaservice luaservice.Manager LuaService.idl /modbus devsettings.Modbus Modbus.idl /modbus/gateway modbus.GatewayMgr ModbusGatewayMgr.idl /net net.Net Net.idl /net/diag net.Diagnostics Diagnostics.idl /ns jsonrpc.NameService NameService.idl /production production.Production Production.idl /production/g2_dev peripheral.G2Production PeripheralG2Production.idl /rawcfg rawcfg.RawConfiguration RawConfiguration.idl /res_mon res_mon.ResMon ResMon.idl /security security.Security Security.idl /security/serviceauthorization security.ServiceAuthorization ServiceAuthorization.idl /serial serial.PortDispatcher PortDispatcher.idl /serial/ serial.SerialPort SerialPort.idl /server_ssl_cert cert.ServerSSLCert ServerSSLCert.idl /servermon servermon.ServerMonitor ServerMonitor.idl /session session.SessionManager SessionManager.idl /link// relayed to / on link unit /smtp devsettings.Smtp Smtp.idl /snmp devsettings.Snmp Snmp.idl /storage_mgr webcam.StorageManager StorageManager.idl /system sys.System System.idl /test/Ethernet test.Ethernet testrpc.idl /test/Unit test.Unit TestUnit.idl /test/Usb alias for /usb /usb usb.Usb Usb.idl /webcam_mgr webcam.WebcamManager WebcamManager.idl /wlanlog logging.WlanLog WlanLog.idl /zeroconf devsettings.Zeroconf Zeroconf.idl Legend ------ = ID of PDU (0 or 1 for master, 2..8 for link units) = ID of inlet (zero-based) = ID of overcurrent protector (zero-based) = ID of outlet (zero-based) = ID of outlet group = ID of pole = Login name of user = Name of user role = Index of peripheral device slot (zero-based) = Name of serial port - usually `main` = ID of ADE chip = ID of link PDU (2..8) = Any valid JSON-RPC RID on link PDU