91 int listEventDescs(in vector<string> eventIdPrefix,
92 out vector<EventDesc> eventDescs);
103 vector<string> listActionTypes();
133 int addAction(in
Action action, out
string actionId);
142 int modifyAction(in
Action action);
151 int deleteAction(in
string actionId);
156 vector<Action> listActions();
173 int triggerAction(in
string actionId, out
string errMsg,
174 in vector<KeyValue> context);
193 int testAction(in
Action action, out
string errMsg,
194 in vector<KeyValue> context);
272 int addRule(in
Rule rule, out
string ruleId);
285 int modifyRule(in
Rule rule);
295 int enableRule(in
string ruleId);
305 int disableRule(in
string ruleId);
314 int deleteRule(in
string ruleId);
324 vector<Rule> listRules();
351 int rearmRule(in
string ruleId);
vector< string > actionIds
List of action IDs.
Definition: EventEngine.idl:254
string idComp
Event ID component.
Definition: EventEngine.idl:80
vector< string > id
Event id vector.
Definition: EventEngine.idl:43
Op operation
Logical operation to be applied.
Definition: EventEngine.idl:227
vector< KeyValue > arguments
Action argument map.
Definition: EventEngine.idl:119
Match if the event is asserted.
Definition: EventEngine.idl:221
boolean isAutoRearm
true for auto-rearming rules
Definition: EventEngine.idl:251
Dynamic node.
Definition: EventEngine.idl:73
Type
Event descriptor type.
Definition: EventEngine.idl:71
string name
User-defined name.
Definition: EventEngine.idl:116
Type type
Event type.
Definition: EventEngine.idl:42
string id
Action ID.
Definition: EventEngine.idl:115
string value
Value.
Definition: EventEngine.idl:20
vector< Condition > conditions
List of subordinate conditions.
Definition: EventEngine.idl:230
Type
Event type.
Definition: EventEngine.idl:37
Logical And.
Definition: EventEngine.idl:214
time timeStamp
Timestamp.
Definition: EventEngine.idl:45
State event.
Definition: EventEngine.idl:38
string name
User-defined name.
Definition: EventEngine.idl:248
string id
Rule ID.
Definition: EventEngine.idl:247
Event has a type: a STATE event indicates that a boolean state has been changed, i.e.
Definition: EventEngine.idl:34
Logical Or.
Definition: EventEngine.idl:215
MatchType matchType
Match type.
Definition: EventEngine.idl:228
boolean hasMatched
true if the rule has matched since being armed
Definition: EventEngine.idl:252
boolean isSystem
true for system-defined rules
Definition: EventEngine.idl:249
string dynNodeContext
Dynamic node context.
Definition: EventEngine.idl:79
boolean negate
Negate the result.
Definition: EventEngine.idl:226
Condition is a logical combination of multiple events.
Definition: EventEngine.idl:210
Condition condition
Trigger condition.
Definition: EventEngine.idl:253
Type eventDescType
Event descriptor type.
Definition: EventEngine.idl:77
vector< EventDesc > entries
Child nodes.
Definition: EventEngine.idl:82
MatchType
the match type how to match the event assertion state
Definition: EventEngine.idl:220
vector< KeyValue > arguments
Argument map.
Definition: EventEngine.idl:255
vector< KeyValue > context
Context map.
Definition: EventEngine.idl:46
Op
logical operation to be applied over all conditions and event
Definition: EventEngine.idl:213
string name
User-defined name.
Definition: EventEngine.idl:81
Match if the event is deasserted.
Definition: EventEngine.idl:222
vector< string > eventId
Event ID.
Definition: EventEngine.idl:229
boolean isEnabled
true if the rule is enabled
Definition: EventEngine.idl:250
Helper that is used wherever key/value pairs are required.
Definition: EventEngine.idl:18
string type
Action type.
Definition: EventEngine.idl:118
Intermediate node.
Definition: EventEngine.idl:72
An event descriptor.
Definition: EventEngine.idl:68
An action is a tuple of 'id' (unique within the scope of this event engine), 'name' which is unique a...
Definition: EventEngine.idl:114
A Rule binds an action to a condition.
Definition: EventEngine.idl:246
There is a single event engine instance reachable by a well known reference.
Definition: EventEngine.idl:53
Event::Type eventType
Event type.
Definition: EventEngine.idl:78
boolean asserted
Assertion value.
Definition: EventEngine.idl:44
string key
Key.
Definition: EventEngine.idl:19
boolean isSystem
true for system-defined actions
Definition: EventEngine.idl:117
Event interface.
Definition: AlarmManager.idl:12