Well-known URI Interface File/Alias -------------- --------- ---------- /model/inlet [alias for] /model/pdu/0/inlet /model/ocp [alias for] /model/pdu/0/ocp /model/outlet [alias for] /model/pdu/0/outlet /model/outletgroup pdumodel.OutletGroupManager OutletGroupManager.idl /model/outletgroup/[outlet group ID] pdumodel.OutletGroup OutletGroup.idl /model/outletgroup/[outlet group ID]/activePower sensors.NumericSensor NumericSensor.idl /model/outletgroup/[outlet group ID]/activeEnergy sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID 0=standalone, 1=master (unused), 2-x=slave ID (unused)] pdumodel.Pdu Pdu.idl /model/pdu/[PDU ID]/inlet/[inlet idx 0-based] pdumodel.Inlet Inlet.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/activeEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/activePower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/apparentEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/apparentPower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/current sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/displacementPowerFactor sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/lineFrequency sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/peakCurrent sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/phaseAngle sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/activeEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/activePower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/apparentEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/apparentPower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/current sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/displacementPowerFactor sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/peakCurrent sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/phaseAngle sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/powerFactor sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/reactivePower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/voltage sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/pole/[pole idx 0-based]/voltageLN sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/powerFactor sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/powerQuality sensors.StateSensor StateSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/reactivePower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/residualCurrent (Type A) sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/residualCurrent (Type B) pdumodel.TypeBResidualCurrentNumericSensor TypeBResidualCurrentNumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/residualCurrentStatus pdumodel.ResidualCurrentStateSensor ResidualCurrentStateSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/surgeProtectorStatus sensors.StateSensor StateSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/unbalancedCurrent sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/inlet/[inlet idx]/voltage sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx 0-based] pdumodel.OverCurrentProtector OverCurrentProtector.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/activeEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/activePower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/apparentEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/apparentPower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/current sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/displacementPowerFactor sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/lineFrequency sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/maximumCurrent sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/peakCurrent sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/phaseAngle sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/powerFactor sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/reactivePower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/voltage sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/ocp/[over current protector idx]/trip pdumodel.OverCurrentProtectorTripSensor OverCurrentProtectorTripSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx 0-based] pdumodel.Outlet Outlet.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/activeEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/activePower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/apparentEnergy sensors.AccumulatingNumericSensor AccumulatingNumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/apparentPower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/current sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/displacementPowerFactor sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/lineFrequency sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/maximumCurrent sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/outletState sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/peakCurrent sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/phaseAngle sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/powerFactor sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/reactivePower sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/unbalancedCurrent sensors.NumericSensor NumericSensor.idl /model/pdu/[PDU ID]/outlet/[outlet idx]/voltage sensors.NumericSensor NumericSensor.idl /model/peripheraldevicemanager peripheral.DeviceManager PeripheralDeviceManager.idl /model/peripheraldeviceslot/[slot idx 0-based] peripheral.DeviceSlot PeripheralDeviceSlot.idl /model/peripheraldeviceslot/[slot idx 0-based]/device sensors.Sensor Sensor.idl /model/pmc pdumodel.PowerMeterController PowerMeterController.idl /model/unit pdumodel.Unit Unit.idl /model/ade/[ADE ID] pdumodel.Ade Ade.idl /model/bcm pdumodel.Bcm Bcm.idl /model/assetstriplogger assetmgrmodel.AssetStripLogger AssetStripLogger.idl /model/alertedsensormanager sensors.AlertedSensorManager AlertedSensorManager.idl /auth auth.AuthManager AuthManager.idl /auth/currentUser [alias for] /auth/user/[name of authenticated user sending request] /auth/ldap auth.LdapManager LdapManager.idl /auth/radius auth.RadiusManager RadiusManager.idl /auth/role usermgmt.RoleManager RoleManager.idl /auth/role/[role name] usermgmt.Role Role.idl /auth/user usermgmt.UserManager UserManager.idl /auth/user/[user name] usermgmt.User User.idl /bulk bulkrpc.BulkRequest BulkRequest.idl /bulkcfg bulkcfg.BulkConfiguration BulkConfiguration.idl /cardreader smartcard.CardReaderManager CardReaderManager.idl /cascading cascading.Cascading Cascading.idl /datapush event.DataPushService DataPushService.idl /datetime datetime.DateTime DateTime.idl /debuglog logging.DebugLog DebugLog.idl /diag diag.DiagLogSettings DiagLogSettings.idl /display display.DisplayControl DisplayControl.idl /energywise cew.EnergyWiseManager EnergyWiseManager.idl /event_engine event.Engine EventEngine.idl /event_engine/alarms event.AlarmManager AlarmManager.idl /event_engine/timer_events event.TimerEventManager TimerEventManager.idl /eventlog logging.EventLog EventLog.idl /eventservice event.Service EventService.idl /firmware firmware.Firmware Firmware.idl /cgi-bin/fwupdate_progress.cgi firmware.UpdateStatus FirmwareUpdateStatus.idl /fitness fitness.Fitness Fitness.idl /hwhealth fitness.HardwareHealth HardwareHealth.idl /lhx lhx.Support LhxSupport.idl /luaservice luaservice.Manager LuaService.idl /modbus devsettings.Modbus Modbus.idl /modbus/gateway modbus.GatewayMgr ModbusGatewayMgr.idl /net net.Net Net.idl /net/diag net.Diagnostics Diagnostics.idl /ns jsonrpc.NameService NameService.idl /production production.Production Production.idl /production/g2_dev peripheral.G2Production PeripheralG2Production.idl /rawcfg rawcfg.RawConfiguration RawConfiguration.idl /res_mon res_mon.ResMon ResMon.idl /security security.Security Security.idl /security/serviceauthorization security.ServiceAuthorization ServiceAuthorization.idl /serial serial.PortDispatcher PortDispatcher.idl /serial/ serial.SerialPort SerialPort.idl /server_ssl_cert cert.ServerSSLCert ServerSSLCert.idl /servermon servermon.ServerMonitor ServerMonitor.idl /session session.SessionManager SessionManager.idl /smtp devsettings.Smtp Smtp.idl /snmp devsettings.Snmp Snmp.idl /storage_mgr webcam.StorageManager StorageManager.idl /system sys.System System.idl /test/Ethernet test.Ethernet testrpc.idl /test/Unit test.Unit TestUnit.idl /test/Usb [alias for] /usb /usb usb.Usb Usb.idl /webcam_mgr webcam.WebcamManager WebcamManager.idl /webcam_mgr/webcam/[webcam ID] webcam.Webcam Webcam.idl /wlanlog logging.WlanLog WlanLog.idl /zeroconf devsettings.Zeroconf Zeroconf.idl