Legrand / Raritan / Server Technology Xerus™ JSON-RPC API
Loading...
Searching...
No Matches
Well-Known Resource IDs

All JSON-RPC requests must be directed to a URL on the device's HTTPS service. The path component of this URL is called resource ID (RID). The list below defines the resource IDs for interfaces that serve as entry points into the API:

# Python example: create a proxy for a well-known RID
from raritan.rpc import devsettings
snmp_proxy = devsettings.Snmp("/snmp", agent)
SNMP agent settings interface.
Definition: Snmp.idl:14

In contrast, object references returned from the device typically have cryptic resource IDs like /tfwopaque/pdumodel.Outlet:2.1.9/outlet.0. These "opaque" IDs are subject to change and should not be hard-coded in programs.

See the legend below for the meaning of placeholders like <pdu_id>.

Resource ID Interface Comment
/model/inlet alias for /model/pdu/0/inlet
/model/ocp alias for /model/pdu/0/ocp
/model/outlet alias for /model/pdu/0/outlet
/model/outletgroup pdumodel.OutletGroupManager
/model/outletgroup/<outlet_grp_id> pdumodel.OutletGroup
/model/outletgroup/<outlet_grp_id>/activePower sensors.NumericSensor
/model/outletgroup/<outlet_grp_id>/activeEnergy sensors.NumericSensor
/model/pdu/<pdu_id> pdumodel.Pdu
/model/pdu/<pdu_id>/inlet/<inlet_id> pdumodel.Inlet
/model/pdu/<pdu_id>/inlet/<inlet_id>/activeEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/activePower sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/apparentEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/apparentPower sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/crestFactor sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/current sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/currentThd sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/displacementPowerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/lineFrequency sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/peakCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/phaseAngle sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/activeEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/activePower sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/apparentEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/apparentPower sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/crestFactor sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/current sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/currentThd sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/displacementPowerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/peakCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/phaseAngle sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/powerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/reactivePower sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/voltage sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/voltageThd sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pair_id>/activeEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/activePower sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/apparentEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/apparentPower sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/crestFactor sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/current sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/currentThd sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/displacementPowerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/peakCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/phaseAngle sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/powerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/reactivePower sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/voltage sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/voltageLN sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/voltageThd sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/powerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/powerQuality sensors.StateSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/reactivePower sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/residualCurrent sensors.NumericSensor models with RCM type A
/model/pdu/<pdu_id>/inlet/<inlet_id>/residualCurrent pdumodel.TypeBResidualCurrentNumericSensor models with RCM type B
/model/pdu/<pdu_id>/inlet/<inlet_id>/residualCurrentStatus pdumodel.ResidualCurrentStateSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/surgeProtectorStatus sensors.StateSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/unbalancedCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/unbalancedLineLineCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/unbalancedVoltage sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/unbalancedLineLineVoltage sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/voltage sensors.NumericSensor
/model/pdu/<pdu_id>/inlet/<inlet_id>/voltageThd sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id> pdumodel.OverCurrentProtector
/model/pdu/<pdu_id>/ocp/<ocp_id>/activeEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/activePower sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/apparentEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/apparentPower sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/current sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/displacementPowerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/lineFrequency sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/maximumCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/peakCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/phaseAngle sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/powerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/reactivePower sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/voltage sensors.NumericSensor
/model/pdu/<pdu_id>/ocp/<ocp_id>/trip pdumodel.OverCurrentProtectorTripSensor
/model/pdu/<pdu_id>/outlet/<outlet_id> pdumodel.Outlet
/model/pdu/<pdu_id>/outlet/<outlet_id>/activeEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/activePower sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/apparentEnergy sensors.AccumulatingNumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/apparentPower sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/crestFactor sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/current sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/currentThd sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/displacementPowerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/inrushCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/lineFrequency sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/maximumCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/outletState sensors.StateSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/peakCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/phaseAngle sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/powerFactor sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/reactivePower sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/unbalancedCurrent sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/voltage sensors.NumericSensor
/model/pdu/<pdu_id>/outlet/<outlet_id>/voltageThd sensors.NumericSensor
/model/peripheraldevicemanager peripheral.DeviceManager
/model/peripheraldeviceslot/<dev_slot> peripheral.DeviceSlot
/model/peripheraldeviceslot/<dev_slot>/device sensors.Sensor
/model/pmc pdumodel.PowerMeterController
/model/unit pdumodel.Unit
/model/ade/<ade_id> pdumodel.Ade
/model/sensorlogger sensors.Logger
/model/assetstriplogger assetmgrmodel.AssetStripLogger
/model/alertedsensormanager sensors.AlertedSensorManager
/auth auth.AuthManager
/auth/currentUser usermgmt.User currently authenticated user
/auth/ldap auth.LdapManager
/auth/radius auth.RadiusManager
/auth/role usermgmt.RoleManager
/auth/role/<role_name> usermgmt.Role
/auth/user usermgmt.UserManager
/auth/user/<user_name> usermgmt.User
/bulk bulkrpc.BulkRequest
/bulkcfg bulkcfg.BulkConfiguration
/cardreader smartcard.CardReaderManager
/cascade cascading.CascadeManager
/crestron devsettings.Crestron
/datapush event.DataPushService
/datetime datetime.DateTime
/debuglog logging.DebugLog
/diag diag.DiagLogSettings
/display display.DisplayControl
/dooraccesscontrol smartlock.DoorAccessControl
/event_engine event.Engine
/event_engine/alarms event.AlarmManager
/event_engine/timer_events event.TimerEventManager
/eventlog logging.EventLog
/eventservice event.Service
/firmware firmware.Firmware
/cgi-bin/fwupdate_progress.cgi firmware.UpdateStatus
/fitness fitness.Fitness
/hwhealth fitness.HardwareHealth
/keypad smartlock.KeypadManager
/luaservice luaservice.Manager
/modbus devsettings.Modbus
/modbus/gateway modbus.GatewayMgr
/net net.Net
/net/diag net.Diagnostics
/net/services net.Services
/ns jsonrpc.NameService
/production production.Production
/production/g2_dev peripheral.G2Production
/rawcfg rawcfg.RawConfiguration
/redfishcfg devsettings.Redfish /redfish is the published API
/res_mon res_mon.ResMon
/security security.Security
/serial serial.PortDispatcher
/serial/<serial_port> serial.SerialPort
/server_ssl_cert cert.ServerSSLCert
/servermon servermon.ServerMonitor
/session session.SessionManager
/link/<link_id>/<rid> fowarded to <rid> on link unit <link_id>
/smtp devsettings.Smtp
/snmp devsettings.Snmp
/storage_mgr webcam.StorageManager
/system sys.System
/test/Unit test.Unit
/test/Usb usb.Usb alias for /usb
/usb usb.Usb
/webcam_mgr webcam.WebcamManager
/wlanlog logging.WlanLog
/zeroconf devsettings.Zeroconf

Legend

Placeholder Meaning
<pdu_id> ID of PDU (0 or 1 for primary unit, 2..8 for link units)
<inlet_id> ID of inlet (0-based)
<pair_id> ID of line pair
<ocp_id> ID of overcurrent protector (0-based)
<outlet_id> ID of outlet (0-based)
<outlet_grp_id> ID of outlet group
<pole_id> ID of pole
<user_name> Login name of user
<role_name> Name of user role
<dev_slot> Index of peripheral device slot (0-based)
<serial_port> Name of serial port, usually main
<ade_id> ID of ADE chip
<link_id> ID of link unit (2..8)
<rid> Any valid JSON-RPC RID on link unit