Raritan / Server Technology Xerus™ PDU JSON-RPC API
|
All JSON-RPC requests must be directed to a URL on the device's HTTPS service. The path component of this URL is called resource ID (RID). The list below defines the resource IDs for interfaces that serve as entry points into the API:
In contrast, object references returned from the device typically have cryptic resource IDs like /tfwopaque/pdumodel.Outlet:2.1.9/outlet.0
. These "opaque" IDs are subject to change and should not be hard-coded in programs.
See the legend below for the meaning of placeholders like <pdu_id>
.
Resource ID | Interface | Comment |
---|---|---|
/model/inlet | — | alias for /model/pdu/0/inlet |
/model/ocp | — | alias for /model/pdu/0/ocp |
/model/outlet | — | alias for /model/pdu/0/outlet |
/model/outletgroup | pdumodel.OutletGroupManager | |
/model/outletgroup/<outlet_grp_id> | pdumodel.OutletGroup | |
/model/outletgroup/<outlet_grp_id>/activePower | sensors.NumericSensor | |
/model/outletgroup/<outlet_grp_id>/activeEnergy | sensors.NumericSensor | |
/model/pdu/<pdu_id> | pdumodel.Pdu | |
/model/pdu/<pdu_id>/inlet/<inlet_id> | pdumodel.Inlet | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/activeEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/activePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/apparentEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/apparentPower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/crestFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/current | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/currentThd | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/displacementPowerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/lineFrequency | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/peakCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/phaseAngle | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/activeEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/activePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/apparentEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/apparentPower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/crestFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/current | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/currentThd | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/displacementPowerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/peakCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/phaseAngle | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/powerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/reactivePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/voltage | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/linepair/<pair_id>/voltageThd | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pair_id>/activeEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/activePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/apparentEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/apparentPower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/crestFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/current | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/currentThd | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/displacementPowerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/peakCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/phaseAngle | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/powerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/reactivePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/voltage | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/voltageLN | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/pole/<pole_id>/voltageThd | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/powerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/powerQuality | sensors.StateSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/reactivePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/residualCurrent | sensors.NumericSensor | models with RCM type A |
/model/pdu/<pdu_id>/inlet/<inlet_id>/residualCurrent | pdumodel.TypeBResidualCurrentNumericSensor | models with RCM type B |
/model/pdu/<pdu_id>/inlet/<inlet_id>/residualCurrentStatus | pdumodel.ResidualCurrentStateSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/surgeProtectorStatus | sensors.StateSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/unbalancedCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/unbalancedLineLineCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/unbalancedVoltage | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/unbalancedLineLineVoltage | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/voltage | sensors.NumericSensor | |
/model/pdu/<pdu_id>/inlet/<inlet_id>/voltageThd | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id> | pdumodel.OverCurrentProtector | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/activeEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/activePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/apparentEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/apparentPower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/current | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/displacementPowerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/lineFrequency | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/maximumCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/peakCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/phaseAngle | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/powerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/reactivePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/voltage | sensors.NumericSensor | |
/model/pdu/<pdu_id>/ocp/<ocp_id>/trip | pdumodel.OverCurrentProtectorTripSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id> | pdumodel.Outlet | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/activeEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/activePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/apparentEnergy | sensors.AccumulatingNumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/apparentPower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/crestFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/current | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/currentThd | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/displacementPowerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/inrushCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/lineFrequency | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/maximumCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/outletState | sensors.StateSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/peakCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/phaseAngle | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/powerFactor | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/reactivePower | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/unbalancedCurrent | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/voltage | sensors.NumericSensor | |
/model/pdu/<pdu_id>/outlet/<outlet_id>/voltageThd | sensors.NumericSensor | |
/model/peripheraldevicemanager | peripheral.DeviceManager | |
/model/peripheraldeviceslot/<dev_slot> | peripheral.DeviceSlot | |
/model/peripheraldeviceslot/<dev_slot>/device | sensors.Sensor | |
/model/pmc | pdumodel.PowerMeterController | |
/model/unit | pdumodel.Unit | |
/model/ade/<ade_id> | pdumodel.Ade | |
/model/sensorlogger | sensors.Logger | |
/model/assetstriplogger | assetmgrmodel.AssetStripLogger | |
/model/alertedsensormanager | sensors.AlertedSensorManager | |
/auth | auth.AuthManager | |
/auth/currentUser | usermgmt.User | currently authenticated user |
/auth/ldap | auth.LdapManager | |
/auth/radius | auth.RadiusManager | |
/auth/role | usermgmt.RoleManager | |
/auth/role/<role_name> | usermgmt.Role | |
/auth/user | usermgmt.UserManager | |
/auth/user/<user_name> | usermgmt.User | |
/bulk | bulkrpc.BulkRequest | |
/bulkcfg | bulkcfg.BulkConfiguration | |
/cardreader | smartcard.CardReaderManager | |
/cascade | cascading.CascadeManager | |
/crestron | devsettings.Crestron | |
/datapush | event.DataPushService | |
/datetime | datetime.DateTime | |
/debuglog | logging.DebugLog | |
/diag | diag.DiagLogSettings | |
/display | display.DisplayControl | |
/dooraccesscontrol | smartlock.DoorAccessControl | |
/event_engine | event.Engine | |
/event_engine/alarms | event.AlarmManager | |
/event_engine/timer_events | event.TimerEventManager | |
/eventlog | logging.EventLog | |
/eventservice | event.Service | |
/firmware | firmware.Firmware | |
/cgi-bin/fwupdate_progress.cgi | firmware.UpdateStatus | |
/fitness | fitness.Fitness | |
/hwhealth | fitness.HardwareHealth | |
/keypad | smartlock.KeypadManager | |
/luaservice | luaservice.Manager | |
/modbus | devsettings.Modbus | |
/modbus/gateway | modbus.GatewayMgr | |
/net | net.Net | |
/net/diag | net.Diagnostics | |
/net/services | net.Services | |
/ns | jsonrpc.NameService | |
/production | production.Production | |
/production/g2_dev | peripheral.G2Production | |
/rawcfg | rawcfg.RawConfiguration | |
/redfishcfg | devsettings.Redfish | /redfish is the published API |
/res_mon | res_mon.ResMon | |
/security | security.Security | |
/serial | serial.PortDispatcher | |
/serial/<serial_port> | serial.SerialPort | |
/server_ssl_cert | cert.ServerSSLCert | |
/servermon | servermon.ServerMonitor | |
/session | session.SessionManager | |
/link/<link_id>/<rid> | — | fowarded to <rid> on link unit <link_id> |
/smtp | devsettings.Smtp | |
/snmp | devsettings.Snmp | |
/storage_mgr | webcam.StorageManager | |
/system | sys.System | |
/test/Unit | test.Unit | |
/test/Usb | usb.Usb | alias for /usb |
/usb | usb.Usb | |
/webcam_mgr | webcam.WebcamManager | |
/wlanlog | logging.WlanLog | |
/zeroconf | devsettings.Zeroconf |
Placeholder | Meaning |
---|---|
<pdu_id> | ID of PDU (0 or 1 for primary unit, 2..8 for link units) |
<inlet_id> | ID of inlet (0-based) |
<pair_id> | ID of line pair |
<ocp_id> | ID of overcurrent protector (0-based) |
<outlet_id> | ID of outlet (0-based) |
<outlet_grp_id> | ID of outlet group |
<pole_id> | ID of pole |
<user_name> | Login name of user |
<role_name> | Name of user role |
<dev_slot> | Index of peripheral device slot (0-based) |
<serial_port> | Name of serial port, usually main |
<ade_id> | ID of ADE chip |
<link_id> | ID of link unit (2..8) |
<rid> | Any valid JSON-RPC RID on link unit |