Add Nodes CSV File Requirements

The nodes CSV file defines the nodes, interfaces, and their details required to add them to CC-SG.

When importing DRAC, ILO and RSA interfaces, you must specify both the KVM interface and the Power interface, or the import will fail.

Column number

Tag or value

Details

1

ADD

The first column for all tags is the command.

2

NODE-DRAC-KVM-INTERFACE for DRAC KVM interfaces

NODE-DRAC-POWER-INTERFACE for DRAC Power interfaces

NODE-ILO-KVM-INTERFACE for iLO KVM interfaces

NODE-ILO-POWER-INTERFACE for iLO Power interfaces

NODE-INT-ILO2-POWER-INTERFACE for Integrity ILO2 Power interfaces

NODE-RSA-POWER-INTERFACE for RSA Power interfaces

Enter the tag as shown.

Tags are not case sensitive.

3

Node Name

Required field.

4

Interface Name

Required field.

5

IP Address or Hostname

Required field.

6

Service Account Name

You must enter either a service account or a username and password.

Leave blank if specifying username and password.

7

Username

You must enter either a service account or a username and password.

Leave blank if specifying service account.

8

Password

You must enter either a service account or a username and password.

Leave blank if specifying service account.

9

Description

Optional.

10*

TCP Port

*For NODE-DRAC-POWER-INTERFACE only, specify a TCP port.

Default is 22.

Specify a username and password for an account that has access to both the chassis and the blade.

Column number

Tag or value

Details

1

ADD

The first column for all tags is the command.

2

NODE-UCS-KVM-INTERFACE

Enter the tag as shown.

Tags are not case sensitive.

3

Node Name

Required field.

4

Interface Name

Required field.

5

UCS Chassis IP address or hostname

Required field.

6

TCP Port

Default is 443.

7

Blade IP address or hostname

 

8

Service Account Name

Optional. Leave blank if specifying username and password.

9

Username

Optional. Leave blank if specifying service account.

10

Password

Optional. Leave blank if specifying service account.

11

Description

Optional.

When importing DRAC, ILO and RSA interfaces, you must specify both the KVM interface and the Power interface, or the import will fail.

Column number

Tag or value

Details

1

ADD

The first column for all tags is the command.

2

NODE-RSA-KVM-INTERFACE

Enter the tag as shown.

Tags are not case sensitive.

3

Node Name

Required field.

4

Interface Name

Required field.

5

IP Address or Hostname

Required field.

6

TCP Port

Default is 2000

7

Service Account Name

Leave blank if specifying username and password.

8

Username

Leave blank if specifying service account.

9

Password

Leave blank if specifying service account.

10

Description

Optional.

See Power Control of Power IQ IT Devices for details about configuring this interface type.

Column number

Tag or value

Details

1

ADD

The first column for all tags is the command ADD.

2

NODE-POWER-PIQ-INTERFACE

Enter the tag as shown.

Tags are not case sensitive.

3

Node Name

Required field.

4

Interface Name

Required field.

5

External Key

  • If the IT device has already been added to Power IQ, find the external key on the IT device's page in the Data Center tab, and enter the text in this field.
  • If the IT device has not been added to Power IQ yet, enter a text value, but make sure to use the same value when adding the IT device to Power IQ. You can quickly make a file of all node and interface information by exporting. See Export Nodes.

6

Managing Power IQ Name

Enter the name of the Power IQ that manages the IT device. The name must match the value in the Power IQ Device Name field on the Access > Power IQ Services > "Power IQ Device Name" Configuration dialog.

See Configuring Power IQ Services.

7

Description

Optional.

Categories and elements must already be created in CC-SG.

You can assign multiple elements of the same category to a node in the CSV file.

Only the ADD command is supported for categories and elements. You cannot update or delete categories and elements using CSV import.

Column number

Tag or value

Details

1

ADD

The first column for all tags is the command.

2

NODE-CATEGORYELEMENT

Enter the tag as shown.

Tags are not case sensitive.

3

Node Name

Required field.

4

Category Name

Required field.

5

Element Name

Required field.

See Also

Adding, Updating, and Deleting Nodes with CSV File Import

Update Nodes CSV File Requirements

Delete Nodes CSV File Requirements

Sample Nodes CSV File

Import Nodes

Export Nodes