Editing a Policy

When you edit a policy, the changes do not affect users who are currently logged into CC-SG. The changes will go into effect at the next login.

To ensure that your changes go into effect sooner, first enter Maintenance Mode, and then edit policies. When you enter Maintenance Mode, all current users are logged out of CC-SG until you exit Maintenance Mode, when users can log in again. See Maintenance Mode.

  1. On the Associations menu, click Policies. The Policy Manager window opens.
  2. Click the Policy Name drop-down arrow, and then select the policy you want to edit from the list.
  3. To edit the name of the policy, click Edit. An Edit Policy window opens. Type a new name for the policy in the field, and then click OK to change the name of the policy. Optional.
  4. Click the Device Group drop-down arrow, and select the Device Group to which this policy governs access.
  5. Click the Node Group drop-down arrow and select the Node Group to which this policy governs access.
  6. If the policy will cover only one type of group, select a value only for that type.
  7. Click the Days drop-down arrow, and then select which days of the week this policy covers: All (everyday), Weekday (Monday through Friday only) and Weekend (Saturday and Sunday only), or Custom (select specific days).
  8. Select Custom to select your own set of days. The individual day checkboxes will become enabled.
  9. Select the checkbox that corresponds to each day you want this policy to cover.
  10. In the Start Time field, type the time of day this policy goes into effect. The time must be in 24-Hour format.
  11. In the End Time field, type the time of day this policy ends. The time must be in 24-Hour format.
  12. If you selected Control in the Device/Node Access Permission field, the Virtual Media Permission section will become enabled. In the Virtual Media Permission field, select an option to allow or deny access to virtual media available in the selected node or device groups for the designated times and days:
  13. Click Update to save your changes.
  14. Click Yes in the confirmation message that appears.

See Also

Policies for Access Control

Adding a Policy

Deleting a Policy

Support for Virtual Media

Assigning Policies To User Groups