The nodes CSV file defines the nodes, interfaces, and their details required to add them to CC-SG.
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Description |
Optional. |
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Enter the same value as entered for Raritan Port Name. |
4 |
Raritan Device Name |
Required field. The device must already be added to CC-SG. |
5 |
Port Number |
Required field. |
6 |
Blade Slot/KVM Switch Port |
If the node is associated with a blade, enter the slot number. If the node is associated with a tiered generic analog KVM Switch, enter the port number. |
7 |
Raritan Port Name |
If left blank, CC-SG will use the existing port name from the device. If you enter a new name, the name will be copied to the device, with the exception of SX devices. |
8 |
Interface Name |
Enter the same value as entered for Raritan Port Name. |
9 |
Description |
Optional. |
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Enter the same value as entered for Raritan Port Name. |
4 |
Raritan Device Name |
Required field. |
5 |
Port Number |
Required field. |
6 |
Raritan Port Name |
If left blank, CC-SG will use the existing port name from the device. If you enter a new name, the name will be copied to the device, with the exception of SX devices. |
7 |
Interface Name |
Enter the same value as entered for Raritan Port Name. |
8 |
Baud Rate |
Valid for SX ports only. |
9 |
Parity |
Valid for SX ports only. |
10 |
Flow Control |
Valid for SX ports only. |
11 |
Description |
Optional. |
Column number in CSV file |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
IP Address or Hostname |
Required field. |
6 |
TCP Port |
Default is 3389. |
7 |
Service Account Name |
Optional. |
8 |
Username |
Optional. |
9 |
Password |
Optional. |
10 |
User Type |
Default is |
11 |
Keyboard Type |
Default is |
12 |
Description |
Optional. |
13 |
RDP Type |
Default is |
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
IP Address or Hostname |
Required field. |
6 |
TCP Port |
Default is 22 for SSH. Default is 23 for TELNET. |
7 |
Service Account Name |
Optional. Leave blank if specifying username and password. |
8 |
Username |
Optional. Leave blank if specifying service account. |
9 |
Password |
Optional. |
10 |
Description |
Optional. |
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
IP Address or Hostname |
Required field. |
6 |
TCP Port |
Default is 5900. |
7 |
Service Account Name |
Optional. Leave blank if specifying password. |
8 |
Password |
Optional. Leave blank if specifying service account. |
9 |
Description |
Optional. |
When importing DRAC, ILO and RSA interfaces, you must specify both the KVM interface and the Power interface, or the import will fail.
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
IP Address or Hostname |
Required field. |
6 |
Service Account Name |
You must enter either a service account or a username and password. Leave blank if specifying username and password. |
7 |
Username |
You must enter either a service account or a username and password. Leave blank if specifying service account. |
8 |
Password |
You must enter either a service account or a username and password. Leave blank if specifying service account. |
9 |
Description |
Optional. |
10* |
TCP Port |
*For Default is 22. |
Specify a username and password for an account that has access to both the chassis and the blade.
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
UCS Chassis IP address or hostname |
Required field. |
6 |
TCP Port |
Default is 443. |
7 |
Blade IP address or hostname |
|
8 |
Service Account Name |
Optional. Leave blank if specifying username and password. |
9 |
Username |
Optional. Leave blank if specifying service account. |
10 |
Password |
Optional. Leave blank if specifying service account. |
11 |
Description |
Optional. |
When importing DRAC, ILO and RSA interfaces, you must specify both the KVM interface and the Power interface, or the import will fail.
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
IP Address or Hostname |
Required field. |
6 |
TCP Port |
Default is 2000 |
7 |
Service Account Name |
Leave blank if specifying username and password. |
8 |
Username |
Leave blank if specifying service account. |
9 |
Password |
Leave blank if specifying service account. |
10 |
Description |
Optional. |
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
IP Address or Hostname |
Required field. |
6 |
UDP Port |
Default is 623 |
7 |
Authentication |
Default is |
8 |
Interval |
Enter the check interval in seconds. Default is 550. |
9 |
Service Account Name |
Leave blank if specifying username and password. |
10 |
Username |
Leave blank if specifying service account. |
11 |
Password |
Leave blank if specifying service account. |
12 |
Description |
Optional. |
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
Powerstrip Name |
Required field. |
6 |
Outlet |
Required field. |
7 |
Managing Device |
The name of the device that the power strip is connected to. Required field for all power strips except Dominion PX. |
8 |
Managing Port |
The name of the port on the device that the power strip is connected to. Required field for all power strips except Dominion PX. |
9 |
Description |
Optional. |
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
URL |
Required field. |
6 |
TCP Port |
Default is 80. |
7 |
Service Account Name |
Optional. Leave blank if specifying username and password. |
8 |
Username |
Optional. Leave blank if specifying service account. Apostrophe character ' is not supported. |
9 |
Password |
Optional. Leave blank if specifying service account. Apostrophe character ' is not supported. |
10 |
Username Field |
Optional. See Tips for Adding a Web Browser Interface |
11 |
Password Field |
Optional. See Tips for Adding a Web Browser Interface |
12 |
Description |
Optional. |
13 |
Extra Parameter Field Name |
Optional. See Web Browser Interface. |
14 |
Extra Parameter Field Value |
Optional. See Web Browser Interface. |
|
|
Use remaining columns in pairs if you need to add more parameter field names and values. |
See Power Control of Power IQ IT Devices for details about configuring this interface type.
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command ADD. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Interface Name |
Required field. |
5 |
External Key |
|
6 |
Managing Power IQ Name |
Enter the name of the Power IQ that manages the IT device. The name must match the value in the Power IQ Device Name field on the Access > Power IQ Services > "Power IQ Device Name" Configuration dialog. |
7 |
Description |
Optional. |
Categories and elements must already be created in CC-SG.
You can assign multiple elements of the same category to a node in the CSV file.
Only the ADD command is supported for categories and elements. You cannot update or delete categories and elements using CSV import.
Column number |
Tag or value |
Details |
---|---|---|
1 |
|
The first column for all tags is the command. |
2 |
|
Enter the tag as shown. Tags are not case sensitive. |
3 |
Node Name |
Required field. |
4 |
Category Name |
Required field. |
5 |
Element Name |
Required field. |